Fire & Smoke

Fire & SmokeFire resistance and smoke leakage performance criteria for doorsets results from a combination of inter-connected British Standards, regulations and legislation. Compliance with the appropriate legislation is paramount for Doorset Technology and all our fire and smoke rated doorset solutions have undergone extensive testing by UKASS accredited test laboratories and successfully achieved certified performance levels for:- 

  • BS 476 Part 22 for FD30 to FD120
  • BS 476 Part 31.1 for smoke leakage
  • Configurations that include single and double leaf assemblies with or without over panels
  • Very broad range of vision panel styles and sizes.
  • Associated glazed screens
  • Coupled with acoustic & mechanical performance

Other related design features include:-

  • Frame materials of steel, aluminium, softwood, hardwood, veneer wrapped MDF or MDF primed for paint
  • Door leaf core constructions that include solid softwood laminated, solid particleboard, flaxboard/particleboard stile & rail
  • Acrovyn 2mm thick PVC encapsulated doors and frames
  • Lead shielding constructions including glazing
  • Door face options:- veneer, HPL, PVC and EBC paint finish
  • Privacy viewing panels
  • Heritage design solid timber doors